IP House

icon Arrange a tour with us today, call +44 (0)20 3130 9444

Our Docklands3 facility offers robust, value colocation in London's data centre hub. Within this location we provide:

  • London Docklands location – close to East India Dock DLR Station and Canning Town
  • Carrier Neutral – connected to Backbone Connect, BT, Energis/C&W/THUS, Datahop, Abovenet, Telia
  • Full racks and private suites available
  • Up to 6kW per rack power density
  • 24/7 access
  • On-site parking

Situated in the heart of the London Docklands area, our IP House facility is perfect if you’re looking for a data centre in central London.

Location

Our IP House facility is located in the heart of the London Docklands area, just 15 minutes from the City of London. With easy access to local transport, the data centre is just a few minutes walk from Canning Town Underground station on the Jubilee line and Docklands Light Railway, and also a short walk to the East India DLR station. There is also onsite parking if you prefer to visit by car. Local amenities include a range of shops, restaurants and cafés within close walking distance.

Connectivity

This carrier neutral facility offers you a range of service options, so you can choose between BT, Energis/C&W/THUS, Datahop, Abovenet and Telia, amongst others. You also benefit from connection to the Backbone Connect network and Metro Ring.

Within the centre you can access national and international MPLS, and Ethernet Access is available from 10Mb to 10Gb.

Power

Power is available from 1kW to 6kW per rack footprint, so your specific needs can be easily catered for, and each rack receives UPS protected dual 16amp supplies. The facility has N+1 current 3 x 500 KVA in parallel with infrastructure, so more units can be added as the load requires. Dual FG Wilson generators are in operation and produce 980KVA each.

Building

A dedicated facilities management team operate onsite 24 hours a day, 7 days a week, ensuring the centre is running at capacity and that your equipment is safe and secure. The building also has a full electronic access control system and is manned 24/7 by vetted security staff. You are able to visit the site and attend to your equipment 24 hours a day.

Temperature and humidity levels are all kept to industry accepted standards in the technical space, and they are maintained within energy efficient parameters. FM200 gas protection is provided in all rooms and in the UPS/battery room, and the centre has a minimum N+1 resilience on its chilled water cooling system.

If you’re looking for quality colocation services on a tight budget, this centrally located data centre is hard to beat.

Find out more

  • This field is for validation purposes and should be left unchanged.


Rack Profile

  • 42u Racks available as part rack, full rack, private suites and caged areas
  • Front and rear mesh doors for ventilation
  • Includes mechanical locks to both doors
  • Dual power presentation in primary and standby configuration

Connectivity

  • Directly connected to the Backbone Connect network and Metro Ring
  • Carrier neutral facility - on net for BT, Energis/C&W/THUS, Datahop, Abovenet, Telia
  • National and international MPLS
  • Ethernet Access 10Mb to 10Gb
  • ADSL, FTTC, EFM and WiMAX
  • Resilient Internet/IP Network Infrastructure

Site Access

  • 5 Minutes walk from East India Dock DLR station and close to Canning Town
  • Lorry access to delivery point. Facilities provided: secure delivery area, secure storage area, secure rack build area, ramp to computer floor.
  • 24 x 7 manned site with 24 x 7 access
  • Onsite parking
  • Full electronic access control system

Power

  • Power available from 1kW to 6kW per rack footprint
  • Single dedicated incomer
  • UPS protected, dual 16amp supplies to each rack.
  • N+1 current 3 x 500 KVA in parallel with infrastructure to add more units as load requires
  • Dual FG Wilson generators @ 980KVA each

Building Overview

  • Dedicated 24x7 facilities management team
  • VESDA detection provided above and below computer floor level
  • FM200 gas protection provided in all rooms and UPS/battery room
  • Minimum N+1 resilience on chilled water cooling system
  • Temperature and humidity in technical space to industry accepted standards and maintained within energy efficient parameters