Our Central London colocation facility is located within the Level3 Goswell Road data centre. Within this location we provide:

  • Premium, Tier III+ facility
  • Central London location
  • Connection to many national and international carriers
  • Part racks, full racks and private suites available
  • Up to 6kW per rack power density
  • On-site parking
  • 24/7 access

Level 3 Goswell Road is ideal if you’re looking for highly resilient colocation space with close links to the City of London.

Location

The centre sits in the heart of London, situated on Goswell Road in the London borough of Islington. The facility is approximately 15 minutes walk from Angel Underground Station on the Northern Line, and around 15 minutes walk from Old Street station, also on the Northern Line and with national rail links. There is also on-site parking if you prefer to visit by car. Local amenities include a variety of restaurants, shops and coffee shops.

Connectivity

You can choose which provider is best for you, as the facility is well connected for both Internet Access and WAN connectivity from over 400 carriers and CDN providers including Level 3 Communications, NTT, Cogent, BT Openreach, Verizon, Colt, KCOM, Virgin Media Business, Cable and Wireless and many others. You’ll also benefit from connection to the Backbone Connect multi-carrier metro network.

Power

You’ll get flexibility when it comes to your power requirements, as the centre offers available power from 1kW to 6kW per rack footprint. The facility also has five 3.8MVA 11kV diesel-driven emergency power generators to safeguard against power outages and reduce the chance of down time.

Building

Your infrastructure is in good hands with a dedicated facilities management team monitoring the premises 24 hours a day, 7 days a week. Temperature and humidity levels are regularly monitored and controlled to ensure optimum conditions for your racks, and high sensitivity smoke detection devices are present in the return airflow of CCUs.

Your racks are also very secure, with CCTV, 24/7 security presence, and the building has a full electronic access control system, based on proximity cards, PIN keypads and biometric palm-scanners.

With 24/7 access to your racks, and our team of experts on hand to troubleshoot any problems, this is an excellent choice for colocation data centre space in the heart of London.

Find out more

  • This field is for validation purposes and should be left unchanged.


Rack Profile

  • 47u Racks available as part rack, full rack, private suites and caged areas
  • Front and rear mesh doors for ventilation.
  • Includes mechanical locks to both doors
  • Dual power presentation in primary and standby configuration

Connectivity

  • Carrier neutral data centre on net to all major carriers and CDN providers including Level 3 Communications, NTT, Cogent, BT Openreach, Verizon, Colt, KCOM, Virgin Media Business, Cable and Wireless and many more
  • Connected to the Backbone Connect multi-carrier metro network
  • Tier 1 IP backbone
  • 2 dedicated Meet Me Rooms
  • Diverse cable entry points
  • Roof space availability for satellite and antennae equipment

Site Access

  • 15 minutes' walk from Old Street and Angel tube stations
  • 24 x 7 access
  • Full electronic access control system, based on proximity cards, PIN keypads and biometric palm-scanners
  • Onsite parking
  • Dedicated loading areas

Power

  • Power available from 1kW to 8kW per rack footprint
  • Dual redundant A & B distribution
  • Minimum N+1 redundancy on power supply
  • Mains power supplied via 3 x 11kV supplies for 4 transformers
  • Dual redundant 20MVA, 33kV dedicated underground mains feeds
  • 5 x 3.8MVA 11kV diesel-driven emergency power generators
  • 3 separate systems of 5 x 625kVA hybrid rotary UPS modules providing 2500kVA output each with N+1 redundancy

Building Overview

  • Dedicated 24x7 facilities management team
  • Minimum N+1 resilience on chilled water cooling system
  • Temperature and humidity in technical space to industry accepted standards and maintained within energy efficient parameters
  • High Sensitivity Smoke Detection (HSSD) devices and alarm system in the return air-flow of CCUs
  • Gas fire suppression system using Argonite / Inergen
  • Smoke and gas extraction