Backbone Connect Docklands Global Switch
Backbone Connect’s Docklands Data centre is one of Europe’s largest purpose-built facilities, offering scalable, resilient space solution.
The facility is situated within close proximity to the main fibre routes, and is underpinned by a minimum N+1 standard for power and cooling systems, delivering and optimal operating environment to clients 24x7.

 |
Overview:
Backbone Connect’sDocklands Data centre is one of Europe’s leading purpose-built facilities, offering scalable, resilient space solution. The facility is situated within close proximity to the main fibre routes, and is underpinned by a minimum N+1 standard for power and cooling systems, delivering and optimal operating environment to clients 24x7.
Technical Details
Key Features
- Gross Area 65,545m2 (705,984ft2)
- Single Racks, Caged Areas and Private Suites available
- 733 watts per square metre cooling
- Metered power
- N+1 power and air conditioning
- Steel frame, concrete floors, metal faced cladding and glazing
- Floor loading of 10kN/m2
- 5m slab to slab height equating to 4.25m clear height to underside of deepest beam
- Raised floors with anti-static tiles and a minimum height of 600mm installed in fully fitted areas, providing minimum clear height of 3.65m to underside of deepest beam
- Column spacing primarily based on a 6m grid
- Passenger lifts x 6 (8 people max per lift)
- Goods lift (7.5 tonnes)
Power (mains and emergency)
- Minimum N+ 1 redundancy on power supply
- Mains power supplied via 2x 132kV incomers
- Diverse A&B supply, distributed via 11kV ring main units
- 3.1MW of power per floor plate
- Power /cooling systems supported by up to 33 no-break Rotary Diesel UPS sets
- On-site diesel tanks (4X119, 000litres) support 50 hours at full capacity with 8 hour, 24x 7 fuel delivery callout contracts in place.
Controlled environment
- Minimum N +1 resilience on chilled water cooling system
- Temperature in technical space maintained at 22oC (+/- 2oC)
- Humidity range of 50% (+/-10%) in technical areas
- Up to 25 air cooled chillers installed, supplying 1.4MW of cooling per chiller
- Close control units (CUUs) provide conditioned air to technical space
- Diverse chilled water distribution pipe work (ring main type) throughout facility
Fire detection and suppression
- Analogue addressable fire detection system in all areas (smoke and heat) with manual break-glass units
- Very early smoke detection and alarm system (VESDA) in the return air-flow of CCUs
- Gas suppression system using centrally stored Inergen to technical and selected landlord areas
- Sprinklers in corridors and selected plant rooms, with water ingress protection and monitoring provided where required
- Dry risers to all floors
- Smoke and gas extraction
Telecommunications
- Carrier Neutral Data Centre
- Level 3 Enabled location
- Access to multiple telecommunications providers located in dedicated Meet Me Rooms (MMRs), via diverse dedicated connection
- Diverse cable entry points (x4) with combination of 110mm ducts and 32mm sub ducts
- Basket trays in three-sided format to o all data risers- fully access controlled
- Multiple connection points to each suite
- Roof space availability for satellite & antennae equipment within Campus
Building management
- Dedicated 24x7 facilities management team
- BMS system monitors M&E operation within facility to :
- Ensure stability of the environment
- Monitor key electrical and mechanical systems
- Enable interface between key systems
- Provide data gathering
- Interlink safety systems in the event of fire alarm activation
Security
- Premises Controllers manage facility security 24x7
- Access control using proximity card readers
- Intruder alarms to all areas with external infra-red barrier
- Multiple CCTV cameras (interior and exterior)
- Secure managed delivery and loading area
Ancillary services
- Private office space can be fitted out to customer specification
- Bookable conference rooms available in landlord area
Package Offers
- 1 x 47u Cabinet From £995 per month
- 5 x 47u Cabinets £4,495 per month